Digital flow meter for heating ventilation air conditioning
Item No.:DG-EFM004
MOQ:1 pc
Application:
√ Central air-conditioning
√ Heating industry
√ Heat exchanger unit
Advantages:
√ No pressure loss, the measurement is not affected by temperature、pressure and other changes.
√ A heat insulation device between the transducer and the sensor to prevent the transfer of temperature
√ Dual current output or double pulse output (positive and negative flow rate respectively) can be selected.
√ The BACnet communication protocol can be selected.
√ Excellent low flow rate measurement performance with a 400:1 turndown ratio
√ The four-electrode structure is suitable for the installation and measurement of various process pipelines, including plastic pipes, fluoride-lined pipes and cement pipes, etc., without the need for another grounding ring.
√ Reliable empty pipe detection technology
√ Five-segment nonlinear correction function
√ Both the power supply and the output circuit adopt reliable lightning protection and surge protection, with high reliability and low fault.
√ The measurement is stable and the stability is excellent
Performance parameters:
■ Accuracy grade: 0.25 and 0.5
■ Repeatability: ±0.1% of measured value
■ Response time: the maximum 0.3 milliseconds relative to the input change.
■ Stability: the stability over 6 months is ±0.1% of measured value
■ Impact of ambient temperature: ±0.25% over operating temperature range
■ Impact of the installation location: the installation is not affected as long as the sensor can be fully charged and enough straight sections are ensured before and after
■ Startup time: it takes 50 milliseconds to start from zero flow
■ Preheating time: it takes 15 minutes from power supply to rated measurement accuracy
Sensor parameters:
Nominal diameter |
3/8 inch to 32 inch ( DN10 to DN800 ) |
The measured fluid conductivity requirements |
≥ 5 μS/cm |
Temperature range of the measured fluid |
- 29 to 150 ℃ (PTFE lining); -29 to 80 (rubber lining); -29 to 180 (PFA lining) |
Body material |
SUS304 stainless steel |
Flange material and shell |
carbon steel, SUS304 stainless steel (optional) |
Shell coating |
anti-corrosion polyester paint |
Lining material |
PTFE, neoprene, PFA and polyurethane linings, etc. |
Electrode material |
316L, Hastelloy B2/C276, Titanium, Tantalum, Platinum, Tungsten Carbide, etc. |
Process connection |
DIN PN10 to PN250 ; ANSI Class 150 / class 300; JIS10 /JIS20K |
Excitation coil impedance |
Maximum 115 ohms |
Sensor protection level |
IP65、IP68 |
Converter parameters:
Ambient temperature range |
- 20 to 149 of (- 29 to 65 ℃) |
Shell material |
low copper die-casting aluminum (standard), or stainless steel material converter shell |
Power |
AC 86 to 265V, 50/60HZ, 1A fast fuse insurance; DC 16V to 36V, 1A fast fuse insurance |
Output |
4-20 mA output, pulse or frequency output |
Communication protocol |
RS485 communication, Hart protocol and Profibus-DP protocol can be selected. |
Protection level |
IP65 |
Correction |
10-segment nonlinear correction |
LCD display |
showing instantaneous flow, total volume, flow rate, etc. |
Excitation current |
Three amplitude excitation technology,excitation current 250mA |
Electrical Interface |
2 PG13.5 |
Power |
10 watts |
Flow measurement range